Generation 8 Modules
u-blox Generation 8 Modules can be configured with the u-center software.
Receivers
- CAM-M8 variants
- EVA-M8 variants
- LEA-M8 variants
- MAX-M8 variants
- NEO-M8 variants
- ZOE-M8 variants
L1 SBAS
- Connect the u-blox receiver to a Windows computer via USB cable.
- In u-center connect to the receiver: Receiver → Connection → COMX.
- Open the configuration view: View → Configuration View.
- Scroll down to GNSS (GNSS Config) and set the following:
SBAS configure: On
SBAS enable: On
Click Send message. Scroll down to SBAS (SBAS Settings) and set the following:
Subsystem: Enabled
Allow test mode use (Msg 0): On
Ranging (Use SBAS in NAV): Off
Apply SBAS Correction data: On
Apply integrity information: Off
Number of search channels: 3
PRN Codes: Other, 122
Click Send message.
Save settings to receiver memory (if you want settings to persist after reboot):
Scroll to CFG (Configuration).
Click Save current configuration.
Highlight all devices (BBR, FLASH, I2C-EEPROM, SPI-FLASH).
Click Send message.
Generation 9 Modules
u-blox Generation 9 Modules can be configured with the u-center software.
Receivers
- NEO-F9 variants
- NEO-M9 variants
- ZED-F9 variants
L1 SBAS
- Connect the u-blox receiver to a Windows computer via USB cable.
- In u-center connect to the receiver: Receiver → Connection → COMX.
- Open the configuration view: View → Configuration View.
Scroll down to GNSS (GNSS Config) and set the following:
SBAS configure: On
SBAS enable: On
Click Send message.
Scroll down to SBAS (SBAS Settings) and set the following:
Subsystem: Enabled
Allow test mode use (Msg 0): On
Ranging (Use SBAS in NAV): Off
Apply SBAS Correction data: On
Apply integrity information: Off
Number of search channels: 3
PRN Codes: Other, 122
Click Send message.
- Save settings to receiver memory (if you want settings to persist after reboot):
- Scroll to CFG (Configuration).
- Click Save current configuration.
- Highlight all devices (BBR, FLASH, I2C-EEPROM, SPI-FLASH).
- Click Send message.
Generation 10 Modules
u-blox Generation 10 Modules can be configured with the u-center 2 software.
Receivers
- MAX-M10 variants
- MIA-M10 variatns
- NEO-F10 variants
L1 SBAS
- Connect the u-blox receiver to a Windows computer via USB cable.
- In u-center connect to the receiver: Devices → Add device → Select COM port → COMX.
- Open the configuration menu: Devices → Device configuration.
Scroll down to CFG-SIGNAL (GNSS Signal Config) and set the following:
CFG-SIGNAL-SBAS_ENA: 1, True
CFG-SIGNAL-SBAS_L1CA_ENA : 1, True
Write each setting to layer RAM (Also set BBR and/or Flash for settings to persist after reboot).
Click Send.
Scroll to CFG-SBAS (SBAS Config) and set the following:
CFG-SBAS-USE_TESTMODE: 1, True
CFG-SBAS-USE_RANGING: 0, False
CFG-SBAS-USE_DIFFCORR: 1, True
CFG-SBAS-USE_INTEGRITY: 0, False
CFG-SBAS-PRNSCANMASK: 4 (Enable search for SBAS PRN122)
Write each setting to layer RAM (Also set BBR and/or Flash for settings to persist after reboot).
Click Send.